Self-Test/Self-Diagnostic Options
Unit Information - Available on the following units by using the -SD suffix
Model Number |
Std. Lamp Wattage |
1.5 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
Battery |
Shape |
2ET6S5 |
6 |
12 |
9 |
6 |
- |
- |
- |
- |
- |
(1) S65 |
Rect. |
2ET6S8 |
9 |
18 |
14 |
9 |
7 |
- |
- |
- |
- |
(1) S68 |
Rect. |
2ET6S8-8 |
8 |
18 |
14 |
9 |
7 |
- |
- |
- |
- |
(1) S68 |
Round |
H2ET6S10 † |
12 |
32 |
24 |
16 |
12 |
10 |
8 |
7 |
6 |
(1) S610SL |
Round |
H2ET6S16 † |
12 |
45 |
36 |
24 |
18 |
14 |
12 |
10 |
9 |
(2) S68 |
Round |
H2ET12S7 † |
12 |
36 |
27 |
18 |
14 |
11 |
9 |
8 |
7 |
(2) S68 |
Round |
2ET6N4 |
6 |
12 |
9 |
6 |
- |
- |
- |
- |
- |
(1) N64F |
Rect. |
2ET6N7 |
9 |
25 |
18 |
14 |
9 |
- |
- |
- |
- |
(1) N67F |
Rect. |
2ET12N4 |
9 |
25 |
18 |
14 |
9 |
- |
- |
- |
- |
(2) N64F |
Rect. |
2ET12N7 |
9 |
50 |
36 |
24 |
18 |
14 |
12 |
10 |
9 |
(2) N67F |
Rect. |
H2ET6N4 |
6 |
12 |
9 |
6 |
- |
- |
- |
- |
- |
(1) N64F |
Rect. |
H2ET6N7 † |
12 |
25 |
18 |
14 |
9 |
- |
- |
- |
- |
(1) N67F |
Rect. |
H2ET12N4 † |
12 |
25 |
18 |
14 |
9 |
- |
- |
- |
- |
(1) N64F |
Round |
H2ET12N7 † |
12 |
50 |
36 |
24 |
18 |
14 |
12 |
10 |
9 |
(2) N67F |
Round |
2RL6S5-R |
6 |
12 |
9 |
6 |
- |
- |
- |
- |
- |
(1) S65 |
Round |
2RL6S5-PH |
6 |
12 |
9 |
6 |
- |
- |
- |
- |
- |
(1) S65 |
Rect. |
2RL6S8-R |
9 |
18 |
14 |
9 |
7 |
- |
- |
- |
- |
(1) S68 |
Round |
2RL6S8-PH |
9 |
18 |
14 |
9 |
7 |
- |
- |
- |
- |
(1) S68 |
Rect. |
2RL6S10-R |
9 |
32 |
24 |
16 |
12 |
- |
- |
- |
- |
(1) S610SL |
Round |
2RL6S10-PH |
9 |
32 |
24 |
16 |
12 |
- |
- |
- |
- |
(1) S610SL |
Rect. |
H2RL6S10 † |
12 |
32 |
24 |
16 |
12 |
- |
- |
- |
- |
(1) S610SL |
Round |
2RL6N4-R |
6 |
12 |
9 |
6 |
- |
- |
- |
- |
- |
(1) N64F |
Round |
2RL6N4-PH |
6 |
12 |
9 |
6 |
- |
- |
- |
- |
- |
(1) N64F |
Rect. |
2RL6N7-R |
9 |
25 |
18 |
14 |
9 |
- |
- |
- |
- |
(1) N67F |
Round |
2RL6N7-PH |
9 |
25 |
18 |
14 |
9 |
- |
- |
- |
- |
(1) N67F |
Rect. |
H2RL6N7 † |
12 |
25 |
18 |
14 |
9 |
- |
- |
- |
- |
(1) N67F |
Round |
2BR6S8 |
8 |
18 |
14 |
9 |
7 |
- |
- |
- |
- |
(1) S68 |
|
H2BR6S10 † |
12 |
32 |
24 |
16 |
12 |
10 |
8 |
7 |
6 |
(1) S610SL |
|
2BR6S16 |
8 |
45 |
36 |
20 |
15 |
12 |
10 |
9 |
8 |
(2) S68 |
|
2BR6S20 |
8 |
64 |
50 |
32 |
24 |
19 |
16 |
14 |
12 |
(2) S610SL |
|
2BR6S36 |
8 |
100 |
75 |
50 |
38 |
30 |
25 |
21 |
18 |
(1) S636 |
|
H2BR12S7 † |
12 |
36 |
27 |
18 |
14 |
11 |
9 |
8 |
7 |
(2) S68 |
|
H2BR12S10 † |
12 |
60 |
45 |
36 |
23 |
18 |
15 |
13 |
11 |
(2) S610SL |
|
H2BR12S15 † |
12 |
100 |
75 |
50 |
38 |
30 |
25 |
21 |
18 |
(1) S1215 |
|
2SC6S8 |
8 |
18 |
14 |
9 |
7 |
- |
- |
- |
- |
(1) S68 |
|
2SC6S10 |
8 |
32 |
24 |
16 |
12 |
10 |
8 |
7 |
6 |
(1) S610SL |
|
2SC6S16 |
8 |
45 |
36 |
20 |
15 |
12 |
10 |
9 |
8 |
(2) S68 |
|
2SC6S20 |
8 |
64 |
50 |
32 |
24 |
19 |
16 |
14 |
12 |
(2) S610SL |
|
2SC6S36 |
8 |
100 |
75 |
50 |
38 |
30 |
25 |
21 |
18 |
(1) S636 |
|
H2SC6S10 † |
12 |
32 |
24 |
16 |
12 |
10 |
8 |
7 |
6 |
(2) S610SL |
|
H2SC6S16 † |
12 |
45 |
36 |
20 |
15 |
12 |
10 |
9 |
8 |
(2) S68 |
|
H2SC6S20 † |
12 |
64 |
50 |
32 |
24 |
19 |
16 |
14 |
12 |
(2) S610SL |
|
H2SC6S36 † |
12 |
100 |
75 |
50 |
38 |
30 |
25 |
21 |
18 |
(1) S636 |
|
H2SC12S7 † |
12 |
36 |
27 |
18 |
14 |
11 |
9 |
8 |
7 |
(2) S68 |
|
H2SC12S10 † |
12 |
60 |
45 |
30 |
23 |
18 |
15 |
13 |
11 |
(2) S610SL |
|
H2SC12S15 † |
12 |
100 |
75 |
50 |
38 |
30 |
25 |
21 |
18 |
(1) S1215 |
|
2SC6N7 |
8 |
25 |
18 |
14 |
9 |
- |
- |
- |
- |
(1) N64F |
|
2SC12N7 |
18 |
50 |
36 |
24 |
18 |
14 |
12 |
10 |
9 |
(2) N67F |
|
H2SC6N4 |
6 |
12 |
9 |
6 |
- |
- |
- |
- |
- |
(1) N64F |
|
H2SC6N7 † |
12 |
25 |
18 |
14 |
9 |
- |
- |
- |
- |
(1) N67F |
|
H2SC12N4 † |
12 |
25 |
18 |
14 |
9 |
- |
- |
- |
- |
(2) N64F |
|
H2SC12N7 † |
12 |
50 |
36 |
24 |
18 |
14 |
12 |
10 |
9 |
(2) N67F |
|
2IL6S20 † |
25 |
64 |
50 |
- |
24 |
- |
- |
- |
12 |
(2) S610SL |
|
2IL6S36 † |
25 |
100 |
75 |
- |
75 |
- |
- |
- |
18 |
(1) S636 |
|
2IL6L40 † |
25 |
120 |
90 |
60 |
45 |
36 |
30 |
26 |
23 |
(1) L640 |
|
2IL12S10 † |
25 |
60 |
45 |
- |
23 |
- |
- |
- |
11 |
(2) S610SL |
|
2IL12S15 † |
25 |
100 |
75 |
- |
38 |
- |
- |
- |
18 |
(1) S1215 |
|
2IL12S20 † |
25 |
120 |
90 |
- |
45 |
- |
- |
- |
23 |
(1) S1220 |
|
2IL12S36 † |
25 |
200 |
150 |
- |
76 |
- |
- |
- |
36 |
(2) S636 |
|
2AR6L40 † |
25 |
120 |
90 |
60 |
45 |
36 |
30 |
26 |
23 |
(1) L640 |
|
H2AR6L40 † |
20 |
120 |
90 |
60 |
45 |
36 |
30 |
26 |
23 |
(1) L640 |
|
2SC6S8 |
8 |
18 |
14 |
9 |
7 |
- |
- |
- |
- |
(1) S68 |
|
2SC6S10 |
8 |
32 |
24 |
16 |
12 |
10 |
8 |
7 |
6 |
(1) S610SL |
|
2SC616 |
8 |
45 |
36 |
20 |
15 |
12 |
10 |
9 |
8 |
(2) S68 |
|
2SC6S20 |
8 |
64 |
50 |
32 |
24 |
19 |
16 |
14 |
12 |
(2) S610SL |
|
2SC6S36 |
8 |
100 |
75 |
50 |
38 |
30 |
25 |
21 |
18 |
(1) S636 |
|
H2SC6S10 † |
12 |
32 |
24 |
16 |
12 |
10 |
8 |
7 |
6 |
(2) S610SL |
|
H2SC6S16† |
12 |
45 |
36 |
20 |
15 |
12 |
10 |
9 |
8 |
(2) S68 |
|
H2SC6S20 † |
12 |
64 |
50 |
32 |
24 |
19 |
16 |
14 |
12 |
(2) S610SL |
|
H2SC6S36 † |
12 |
100 |
75 |
50 |
38 |
30 |
25 |
21 |
18 |
(1) S636 |
|
H2SC12S7 † |
12 |
36 |
27 |
18 |
14 |
11 |
9 |
8 |
7 |
(2) S68 |
|
H2SC12S10 † |
12 |
60 |
45 |
30 |
23 |
18 |
15 |
13 |
11 |
(2) S610SL |
|
H2SC12S15 † |
12 |
100 |
75 |
50 |
38 |
30 |
25 |
21 |
18 |
(1) S1215 |
|
2SC6N7 |
8 |
25 |
18 |
14 |
9 |
- |
- |
- |
- |
(1) N64F |
|
2SC12N7 |
18 |
50 |
36 |
24 |
18 |
14 |
12 |
10 |
9 |
(2) N67F |
|
H2SC6N4 |
6 |
12 |
9 |
6 |
- |
- |
- |
- |
- |
(1) N64F |
|
H2SC6N7 † |
12 |
25 |
18 |
14 |
9 |
- |
- |
- |
- |
(1) N67F |
|
H2SC12N4 † |
12 |
25 |
18 |
14 |
9 |
- |
- |
- |
- |
(2) N64F |
|
H2SC12N7 † |
12 |
50 |
36 |
24 |
18 |
14 |
12 |
10 |
9 |
(2) N64F |
|
Life Safety Code (NFPA 101)
SECTION 7.9
EMERGENCY LIGHTING
7.9.3 Periodic Testing of Emergency Lighting Equipment
7.9.3.1 Required emergency lighting systems shall be tested in accordance with one of the three options offered by 7.9.3.1.1, 7.9.3.1.2, 7.9.3.1.3.
7.9.3.1.1 Testing of required emergency lighting systems shall be permitted to be conducted as follows:
(1) Functional testing shall be conducted at 30-day intervals for not less than 30 seconds.
(2) Functional testing shall be conducted annually for not less than 1½ hours if the emergency lighting system is battery powered.
(3) The emergency lighting equipment shall be fully operational for the duration of the test required by 7.9.3.1.1(1) and 7.9.3.1.1(2).
(4) Written records of visual inspections and tests shall be kept by the owner for inspection by the authority having jurisdiction.
7.9.3.1.2 Testing of required emergency lighting systems shall be permitted to be conducted as follows:
(1) Self-testing / self-diagnostic battery-operated emergency lighting equipment shall be provided.
(2) Self-testing / self-diagnostic battery-operated emergency lighting equipment shall automatically perform not less than once every 30 days a test for not less than 30 seconds and a diagnostic routine.
(3) Self-testing / self-diagnostic battery-operated emergency lighting equipment shall indicate failures by a status indicator.
(4) A visual inspection shall be performed at intervals not exceeding 30 days.
(5) Functional testing shall be conducted annually for not less than 1½ hours.
(6) Self-testing / self-diagnostic battery-operated emergency lighting equipment shall be fully operational for the duration of the 1½ hour test.
(7) Written records of visual inspections and tests shall be kept by the owner for inspection by the authority having jurisdiction.
7.9.3.1.3 Testing of required emergency lighting systems shall be permitted to be conducted as follows:
(1) Computer-based, self-testing / self-diagnostic battery-operated emergency lighting equipment shall be provided.
(2) The emergency lighting equipment shall automatically perform not less than once every 30 days a test for not less than 30 seconds and a diagnostic routine.
(3) The emergency lighting equipment shall automatically perform annually a test for not less than 1½ hours.
(4) The emergency lighting equipment shall be fully operational for the duration of the tests required by 7.9.3.1.3(2) and 7.9.3.1.3(3).
(5) The computer-based system shall be capable of providing a report of the history of the tests and failures at all times.
Exerpted from
Life Safety Code 2003
Page 101-67
Print this catalog page (PDF) |